Latest revision as of 18:12, 22 November 2010
Introduction
The OnSpec 90c26 was used on Adara and Microtek flatbed scanners in the
late 1990s as a parallel port to SCSI adapter.
IBM-style Parallel Port Information
Port Registers
Port R/W IOAddr Bits Function
---------- ------ ----- ----------------
Data Out W Base+0 D0-D7 8 LS TTL outputs
Status In R Base+1 S3-S7 5 LS TTL inputs
Control Out W Base+2 C0-C3 4 TTL Open Collector outputs
" " " C4 internal, IRQ enable
" " " C5 internal, Tristate data [PS/2]
Data Feedback R Base+0 D0-D7 matches Data Out
Control Feedbk R Base+2 C0-C3 matches Control Out
" " " C4 internal, IRQ enable readback
The Feedback registers are for diagnostic purposes (except in bidirectional
ports, where Data Feedback is used for data input; and the IRQ enable C4).
Pin signals and register bits
<= in DB25 Cent Name of Reg
=> out pin pin Signal Bit Function Notes
------ ---- ---- -------- --- -----------------------------
=> 1 1 -Strobe C0- Set Low pulse >0.5 us to send
=> 2 2 Data 0 D0 Set to least significant data
=> 3 3 Data 1 D1 ...
=> 4 4 Data 2 D2 ...
=> 5 5 Data 3 D3 ...
=> 6 6 Data 4 D4 ...
=> 7 7 Data 5 D5 ...
=> 8 8 Data 6 D6 ...
=> 9 9 Data 7 D7 Set to most significant data
<= 10 10 -Ack S6+ IRQ Low Pulse ~ 5 uS, after accept
<= 11 11 +Busy S7- High for Busy/Offline/Error
<= 12 12 +PaperEnd S5+ High for out of paper
<= 13 13 +SelectIn S4+ High for printer selected
=> 14 14 -AutoFd C1- Set Low to autofeed one line
<= 15 32 -Error S3+ Low for Error/Offline/PaperEnd
=> 16 31 -Init C2+ Set Low pulse > 50uS to init
=> 17 36 -Select C3- Set Low to select printer
== 18-25 19-30, Ground
33,17,16
Note: Some cables, ports, or connectors may not connect all grounds.
Centronics pins 19-30 and 33 are "twisted pair return" grounds, while
17 is "chassis ground" and 16 is "logic ground".
"<= In" and "=> Out" are defined from the viewpoint of the PC, not the
printer. The IRQ line (-Ack/S6+) is positive edge triggered, but only
enabled if C4 is 1.
Here's the same data grouped for ease of reference by Control Out and Status
In registers and pins. (Data Out is straightforward in previous table).
<= in DB25 Cent Name of Reg
=> out pin pin Signal Bit Function Notes
------ ---- ---- -------- --- ------------------------------
=> 17 36 -Select C3- Set Low to select printer
=> 16 31 -Init C2+ Set Low pulse > 50uS to init
=> 14 14 -AutoFd C1- Set Low to autofeed one line
=> 1 1 -Strobe C0- Set Low pulse > 0.5 us to send
<= 11 11 +Busy S7- High for Busy/Offline/Error
<= 10 10 -Ack S6+ IRQ Low Pulse ~ 5 uS, after accept
<= 12 12 +PaperEnd S5+ High for out of paper
<= 13 13 +SelectIn S4+ High for printer selected
<= 15 32 -Error S3+ Low for Error/Offline/PaperEnd
Physical Layer Protocol
PS/2 and Nibble Modes
Sending a Command
D0-D7 |
<= Command Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
Sending a Value
D0-D7 |
<= Value Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x07 (lower #STROBE, #INIT, and #AUTOFD)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
Read a Register (Nibble Mode)
D0-D7 |
<= Command Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
C0-C3 |
<= 0x06 (lower #AUTOFD and #INIT)
|
S3-S7 |
>= Status Byte 1
|
C0-C3 |
<= 0x04 (lower #INIT)
|
C0-C3 |
<= 0x06 (lower #AUTOFD and #INIT)
|
S3-S7 |
>= Status Byte 2
|
C0-C3 |
<= 0x04 (lower #INIT)
|
Read Value = (Status Byte 1 >> 4) & 0xf) | (Status Byte 2 & 0xf0)
Read a Register (PS/2 Mode)
D0-D7 |
<= Command Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
C0-C3, Tristate Enable |
<= 0x26 (tristate data, #AUTOFD, and #INIT)
|
D0-D7 |
>= Read Value
|
C0-C3 |
<= 0x04 (lower #INIT)
|
Writing Register
D0-D7 |
<= Register Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x0D (lower #STROBE, #INIT, and #SELECT)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
D0-D7 |
<= Value Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x07 (lower #STROBE, #INIT, and #AUTOFD)
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
Writing a Block
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
D0-D7 |
<= Byte 0
|
C0-C3 |
<= 0x07 (lower #STROBE, #AUTOFD, and #INIT)
|
D0-D7 |
<= Byte 1
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
...
|
D0-D7 |
<= Byte N is even
|
C0-C3 |
<= 0x07 (lower #STROBE, #AUTOFD, and #INIT)
|
D0-D7 |
<= Byte N is odd
|
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
Reading a Block (Nibble)
C0-C3 |
<= 0x04 (lower #INIT)
|
C0-C3 |
<= 0x06 (lower #AUTOFD and #INIT)
|
S3-S7 |
>= Status Byte 0
|
C0-C3 |
<= 0x04 (lower #INIT)
|
C0-C3 |
<= 0x06 (lower #AUTOFD and #INIT)
|
S3-S7 |
>= Status Byte 1
|
C0-C3 |
<= 0x04 (lower #INIT)
|
|
Read Value = (Status Byte 1 >> 4) & 0xf) &pipe; (Status Byte 2 & 0xf0)
|
...
|
Reading a Block (PS/2)
C0-C3 |
<= 0x24 (Tristate, lower #INIT)
|
D0-D7 |
>= Read Byte 0
|
C0-C3 |
<= 0x26 (tristate, lower #INIT and #AUTOFD)
|
D0-D7 |
>= Read Byte 1
|
...
|
C0-C3 |
<= 0x24 (tristate, lower #INIT)
|
D0-D7 |
>= Read Byte N even
|
C0-C3 |
<= 0x26 (tristate, lower #INIT and #AUTOFD)
|
D0-D7 |
>= Read Byte N odd
|
EPP Modes
Sending a Command
Sending a Value
Writing a Register
ADDR |
<= Register Byte
|
C0-C3 |
<= 0x05 (lower #STROBE and #RESET)
|
DATA |
<= Value Byte
|
C0-C3 |
<= 0x04 (lower #RESET)
|
Reading a Register
ADDR |
<= Register Byte
|
C0-C3, Tristate Enable |
<= 0x24 (tristate data, lower #INIT)
|
DATA |
>= Read Value
|
C0-C3 |
<= 0x04 (lower #INIT)
|
Writing a Block
...
C0-C3 |
<= 0x05 (lower #STROBE and #INIT)
|
DATA |
<= Data Byte 0
|
DATA |
<= Data Byte 1
|
DATA |
<= Data Byte N
|
Reading a Block
...
C0-C3 Tristate |
<= 0x24 (Tristate, lower #INIT)
|
DATA |
=> Data Byte 0
|
DATA |
=> Data Byte 1
|
DATA |
=> Data Byte N
|
Link Connection
Connect Link
DATA |
<= 0xFE
|
DATA |
<= 0xAA
|
DATA |
<= 0x55
|
DATA |
<= 0x00
|
DATA |
<= 0xFF
|
DATA |
<= 0x87
|
DATA |
<= 0x78
|
DATA |
<= 0x20
|
C0-C3 |
<= 0x05 (lower #INIT and #STROBE)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
DATA |
<= 0xFF
|
Nibble_Command(2)
Nibble_Value(0)
Nibble_Command(2)
NIbble_Value(IsNibbleMode ? 0 : 1)
Write_Register(2, IsNibbleMode ? 0 : 1)
Disconnect Link
Write_Register(3, 0)
Write_Register(7, 0x48)
Command(4)
DATA |
<= 0xFE
|
DATA |
<= 0xAA
|
DATA |
<= 0x55
|
DATA |
<= 0x00
|
DATA |
<= 0xFF
|
DATA |
<= 0x87
|
DATA |
<= 0x78
|
DATA |
<= 0x30
|
C0-C3 |
<= 0x05 (lower #INIT and #STROBE)
|
C0-C3 |
<= 0x04 (lower #INIT)
|
DATA |
<= 0xFF
|
OnSpec 90c26 Registers
Link Layer Protocol
Register |
Type |
Comments
|
0x00 |
R/W |
B0-B6: SCSI Target B7: Initiator Mode
|
0x01 |
R/W |
B0: SCSI Connected/Busy (R/O)
B1: SCSI Enable
B4: SCSI Bus State REQ (R/O)
B5: SCSI Bus State MSG (R/O)
B6: SCSI Bus State CD (R/O)
B7: SCSI Bus State IO (R/O)
|
0x02 |
R/W |
B0: Bi-Direction Mode Enable
B5: Read SCSI Bus status into Register 0x01
B7: SCSI Mode Enable
|
0x03 |
W |
|
0x04 |
R |
ASIC Version
|
0x07 |
W |
B3: Unknown B6: Unknown
|